GW1-10 outdoor high-voltage disconnector is suitable for installation on the outdoor high-voltage distribution equipment line, for the line to cut off the line and convert the line when there is voltage and no load. This product is a three-phase appliance composed of three separate single disconnectors. Each single disconnector has the same components, such as base post insulators, front and rear static contacts, gate blades and arc angles.
-
GW1 outdoor high-voltage disconnector (hereinafter referred to as is) is suitable for installation on outdoor 12KV lines, for the line to divide and combine power when there is voltage and no load.
This disconnector fully takes into account the different needs of users, and is divided into two forms: with grounding knife and without grounding knife. The switch with grounding knife and CS□ manual mechanism can prevent misoperation such as connecting the grounding wire with electricity and closing the isolation switch with the grounding wire, and the operator does not have to hang the grounding wire. There are two kinds of disconnectors: ordinary type and anti-fouling type. Among them, the anti-fouling disconnector can stay in the requirements of more seriously polluted areas, and can effectively solve the problem of pollution flashover in the operation of the disconnector. The products meet the requirements of GB1985 and GB/T11022 standards. -
GW4-12 (17.5/40.5) series outdoor AC high-voltage disconnector suitable device in outdoor AC 50H2. The rated voltage is 17.5KV and 40.5KV respectively, and the line is used as an opening and closing circuit when there is voltage and no load. The products meet the requirements of GB1985 and other relevant standards.
-
All of them are treated with hot-dip galvanizing process for anti-corrosion, and hot-dip galvanizing can not guarantee that the parts that require rotation are generally made of stainless steel, and the fasteners below M8 are made of stainless steel, and the rest are hot-dip galvanized.
-
This product is a double-column horizontal fracture open type in the middle, and a grounding switch can be attached to one or both sides. The 90° transmission isolation switch adopts CS17 type human operation mechanism for triple linkage operation; The isolation switch of 180° transmission adopts CJ6 motor operating mechanism or CS17G human operation mechanism for triple linkage operation; The grounding switch adopts CS17G type human operation mechanism triple linkage operation.
-
This product is a single-break vertical open structure, and the single disconnector pillar insulator is installed on their respective chassis, which is mainly composed of a base, a pillar insulator, a leading electrical circuit part, and a self-locking device. The gate knife structure is used to open and close the gate to achieve cutting and closing the line. Each phase blade is composed of two conductive blades, and both sides of the blade are equipped with compression springs, and the height of the spring can be adjusted to obtain the contact pressure required for the switch blade. When the switch is opened and closed, the insulating hook rod is used to operate the mechanism part, and the gate knife has a self-locking device.
-
(H) GW9-35 series outdoor single-voltage AC disconnector is suitable for three-phase AC 50Hz, rated voltage 35KV and below high-voltage transmission and distribution lines, used to cut off and close the single-phase or three-phase circuit with no load and voltage. Switches are available in 200, 400, 630 and 1000 A ratings. They are all composed of a base pillar insulator, a conductive part and a mechanism part. The gate knife structure is used to close the gate to cut off and close the line. Each phase blade is composed of two conductive plates, and the two sides of the blade are equipped with compression springs, and the contact pressure required by the switch blade can be obtained by adjusting the height of the spring. When the switch is opened and closed, the closing movement can be carried out with an insulated operating mechanism. The gate knife has a self-locking device.
-
The GW13 series neutral disconnector is used to divide the neutral point connection of the transformer under the condition of no load, and can provide an insulation distance that meets the safety requirements when the gate blade is in the normal opening position. The output shaft of the operating mechanism can be rotated horizontally for 180 degrees, and the positioning device on the operating mechanism can ensure that the contact and the static contact are in the correct position or breaking position.
-
110kV, 220kV is the main voltage level of the power supply network, due to the high voltage, the neutral point is generally directly grounded, due to the requirements of relay protection setting configuration and prevention of communication interference, in order to limit the single-phase short-circuit current, some transformers adopt the neutral point is not grounded. In this mode of operation, due to lightning strikes, single-phase grounding short circuit faults, etc., will cause overvoltage at the neutral point, and most of the transformers are graded insulation, so the overvoltage poses a great threat to the insulation of the neutral point, and protection devices must be set up to prevent accidents.
-
HDCR disconnectors are available in single and double column mounting. The installation form can be divided into hanging installation or vertical installation. It can be installed with a single cross arm clamp or a double cross arm (see the product brochure for specific installation diagrams).
-
The DCR disconnector is an outdoor pole single-phase disconnector, which provides a visible break for maintenance personnel and can also be used as a breaking point. Its structure is a double-column disconnector, the insulator and bolt are locked on a hot-dip galvanized base, and the disconnector can be operated by pulling the ring. The limit level after the isolation knife is opened is 160 degrees by default (it can be changed to 90 degrees on the spot or removed to no limit on the spot). When installing the DCR disconnector, an optional mounting backplate can be clamped onto the cross arm to fix the switch.
1